Convert 6 tone alarm to only 1

horacio001
hace 6 años
hace 6 años
Hello community, I tell you ... I acquired a 6-tone Chinese generic alarm of 12 volts that works with an integrated GE6065B and I would like to know if it can be configured to be with a single fixed tone and if you can choose which of them. attached photo ,, thank you very much if you could help me. regards
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. In your case you must act on leg Nº8. Being connected to the positive will generate 1 tone, if not connected it will play all 6. You can even change the frequency of the tones. I leave the integrated datasheet link so you can see its variables. Regards http://www.sc-tech.cn/en/ge6065b.pdf