Jose  Hernandez
hace 6 años
hace 6 años
I need help if anyone has worked with Sabiem electromechanical elevators. This brings several simple electronic cards, what I need is information about the transistors and the zener diodes, since old numbers cannot be seen, this card supplies two voltages, one of 20 volts, top and bottom -35 volts The twenty volts are fine but at -35 volts, there are only -23 volts. Thanks in advance. Annex photo of the card
juite
juite
372
hace 6 años

You could upload a photo from the Cu side, maybe we can redesign the source based on the value of existing components.

Responder
Jose  Hernandez
hace 6 años

OK I will locate all the data of each transistor

Responder
juite
juite
372
hace 6 años

If you put the photo on the back we could trace the circuit.

Responder
JOSE MIGUEL SIRGO PASCUAL
hace 6 años

Second time you ask him to upload a copper side picture. I would not tell you a third time, I would directly forget the subject.

Responder
Jose  Hernandez
hace 6 años

I have not uploaded the photo from the back because I started to try some transistors and I managed to repair the card, we mounted it in the elevator and it worked well, when delivered. I thank colleague Juite for his parents as well as Jose Miguel.

Responder
Jose  Hernandez
hace 6 años
hace 6 años
I managed to decipher the numbers of the transistors of the -35 volt line, replacing them with some of the ones I had in my spare parts bank and the problem was solved. What happened is that the transistors for being very old the rust on their covers did not show the silkscreen of the pampering
Ennio Montenegro.
hace 6 años
hace 6 años
Did you measure the tensions that feed both sources .. ?? If the - 35V is low, check the filter capacitor. If it is greater than - 35V, you can move the SR41 multi-turn potentiometer, a couple of turns clockwise. If it goes up, it is regulating. Comment results
Jose  Hernandez
hace 6 años

Already detect the problem was a transient marked with NTE159 damaged, and as Ennio Montene, the SR41 multiturn potentiometer, was at 300 ohms, 616 ohms being correct. It already worked and we mounted it in the elevator and this work.
Thanks for the support.

Responder
Jose  Hernandez
hace 6 años

Now I have another identical card but the fault is on the +20 Volt line. The problem is replacement transistors as they do not fulfill the functions of the original. The originals no longer get used to the market, what can I do?
Q40 2n2219A or BC141-16 What is the recommended replacement?
Q42 2N2904 or 852D
Q43 2N2222
It reaches 18 volts and stops when moving the trimer.

Responder
Ennio Montenegro.
hace 6 años

It is preferable that you put a new query in Electronic forum and circuits, without component data sheet forum.

Responder
Jose  Hernandez
hace 6 años

Thanks Ennio I will do it. Thank you very much, best regards from Caracas Venezuela. The big problem we have here is that you don't get spare parts.

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis