Second time you ask him to upload a copper side picture. I would not tell you a third time, I would directly forget the subject.
I have not uploaded the photo from the back because I started to try some transistors and I managed to repair the card, we mounted it in the elevator and it worked well, when delivered. I thank colleague Juite for his parents as well as Jose Miguel.
Already detect the problem was a transient marked with NTE159 damaged, and as Ennio Montene, the SR41 multiturn potentiometer, was at 300 ohms, 616 ohms being correct. It already worked and we mounted it in the elevator and this work.
Thanks for the support.
Now I have another identical card but the fault is on the +20 Volt line. The problem is replacement transistors as they do not fulfill the functions of the original. The originals no longer get used to the market, what can I do?
Q40 2n2219A or BC141-16 What is the recommended replacement?
Q42 2N2904 or 852D
Q43 2N2222
It reaches 18 volts and stops when moving the trimer.
It is preferable that you put a new query in Electronic forum and circuits, without component data sheet forum.
Thanks Ennio I will do it. Thank you very much, best regards from Caracas Venezuela. The big problem we have here is that you don't get spare parts.