Hi, I have a 24v prestolite starter that they gave it to me because I did not turn, I did a collector rectification service (with the armature tester is ok), bushings and replace the brushes, the field looks good ... the subject is good ... that by putting it together and trying it, it turns very little and I notice that at least one or more of the brushes is reheated to red and smokes ... with the hand it turns well, it does not work ... I have several doubts and I do not have much time to go testing if it happened to someone I would appreciate it ...
hugodesalta
hugodesalta
2.450
hace 5 años

Probably if something is not grounded, it can be brush holder, induced, fields ... if the inductometer tells you that it is not short, something must be grounded

Responder
Jonatan2018
hace 5 años

How can I do mass testing with the armed engine?

Responder
hugodesalta
hugodesalta
2.450
hace 5 años

You must take it apart to test all the parts, it is the way to be sure.

Responder
Jonatan2018
hace 5 años

Thanks for the input I will disarm again

Responder
hugodesalta
hugodesalta
2.450
hace 5 años

with continuity, and if possible, with the battery directly

Responder
Jonatan2018
hace 5 años

Thanks Hugo for your recommendations ... the rotor in one part is only grounded ... I will send it for repair, so I will replace it with a replacement one. Thank you

Responder
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. The inductor may mark you that it is correct but if you have two or three short fields or derivatives, it will also do so. With a tester check between each brush and the metal body. There should be no measurement. On the other hand, make a good cleaning of the collector between the seaweed and clean the area of the carbon holders. The dust they give off is conductive. regards
Jonatan2018
hace 5 años

Hello thanks for the answer ... I have a question, the test should I do it continuously or on Ohm's scale?

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis