⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Motors and Windings

In a three-phase motor as I identify the coils

alexviez
hace 5 años
hace 5 años
Hello, in a 6-phase three-phase motor as I can identify in principle and the end of each coil since the cables are not identified and can make the proper connection
pablo brandts
hace 5 años
hace 5 años
It's easy brother, first mark all the connection points of the coils, if the motor is 6 points, it has three coils, the way to test them is as follows, the motor connection terminal must have 6 points if it has a terminal block if you do not have a terminal block or having it the same, leave all the connection points isolated one respect the other and you are testing one by one in the continuity test strip, each of the cables must give you continuity with another cable and then list it in this so point 1 must give you continuity with point 4, that is the first coil, point 2 must give you continuity with point 5, that is the second coil and finally point 3 must give you continuity with point 6 that is the third coil and that's it, I hope it helps, success.
pablo brandts
hace 5 años

To test the beginning and end of each coil you should preferably do it with an amperemeter clamp connecting the star or triangle motor as indicated by the plate you put energy and if the consumption of any of the faces is excessive, you reverse that coil and then return to putting energy if it matches is because that is the right sentimental.

Responder
alexviez
hace 5 años

And if the engine is 12 points how would the procedure be? I imagine it is more complex

Responder
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. If I am not mistaken since the motors are not my thing simply with a tester you can identify them. If there are 6 coils and they are not interconnected between them, take a tip and look for its opposite end where there is continuity. You can only measure continuity in one of them. regards
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis