Motors and Windings

my hydropneumatic does not turn off

GERARDO SALINAS
hace 5 años
hace 5 años
my hydropneumatic does not stop at 30 psi and not for the automatic says it is 20 40 and I took the air out of the tank and refilled it with 18 psi change the automatic pressure gauge and still the problem I put a stopcock in the exit to check for possible leaks and still not for pichancha I think it may not be purging well is a 24-liter 1/2 tank engine press cool brand in advance thank you for your attention
Jose  Manobanda
hace 5 años
hace 5 años
Change the pressure switch ... it must be broken
gonzalo rodrigueztecnico
hace 5 años
hace 5 años
greetings gerardo ,, there are several reasons for team not to stop -the pressure may be poorly calibrated ,, if equipment only generates 30 psi and is calibrated at more pressure, it does not stop - remember that to fill the air membrane, the water tank must be empty or will not work ,,, once loaded with air you can fill it with water again ,,, _ Likewise if the water pump worked in a vacuum, that is to say if water damaged the mechanical seal ,, check if the check valve is working well ,, check if the baypas valve is closed and if the water tank that feeds the hydropneumatic has water enter brand and model of equipment review and comment

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis