hace 18 años
1
Familiarize yourself with these instructions, so that the whole procedure is done within 3 minutes. Otherwise, the scale may go into the “AUTO-OFF” mode. Warm up the scale for 10 minutes by turning ON the scale, but being sure to change the load on the pan every 2 minutes. This will maintain the instrument in the ON state.
2
With display ON, tilt up the weighing platform. Find and remove the CALIBRATION SWITCH COVER. This cover is on the underside of the tilt-up portion, toward the center. Move the switch to ON. The display will then show a number beginning with “9”.
3
Press MODE. Display will show CAL 0, with circular stability indicator . If not, turn OFF, then start over.
4
Press ZERO. The display shows CAL 1
Press MODE . The display shows CAL 2
5
Place the weight indicated in this table on the pan. FW-150 100Kg
FW-100 60Kg
FW-60 40Kg
FW-15 10Kg
FW-10 6 Kg
6
Press ZERO after the circular stability indicator comes on. Display will show END.
7
Slide the calibration switch OFF, then turn OFF the scale. Calibration is complete.
____________________________________________________________________________
Calibration with alternate weights is possible. Use these alternate weights by selecting a different CAL # at step 4
CAL 1 CAL 2 CAL 3 CAL 4
FW150 150 Kg 100 Kg 300 lb 200 lb
FW100 100 Kg 60 Kg 200 lb 150 lb
FW60 60 Kg 40 Kg 120 lb 80 lb
FW15 15 Kg 10 Kg 30 lb 20 lb
FW 10 10 Kg 6 Kg 20 lb 15 lb