as a solution I can say that the ic of the front, but also the output is bad and also had to put a USB module sd bluetooth and aux in, the arrangement would be worth more than the equipment is worth in this case is not justified, my recommendation, Check the pin voltages 1,2 and 3 and if the voltages are coming to the ic and the display on the button and there should be 4 to 5 volts if everything is ok is the ic but it is not only possible to get it in google it would only be to buy the full front
what remains as bitter experience is the following, it is better to repair the device and then maintenance and cleaning is done because it happens as in this case that the device is irreparable but it is useless greetings
friend of course I thank you infinitely for your valuable response, I ask you the measurements should be made in ucw 1 or ucw2 ??? thanks for your kind response
friend I already made the measurements, which I recommend, between pin 1 and 3 there are 4 v ac, and between 1 and 2 or 3 and 2 da - 5 votes
having rectified between pin 1 and 3 there are 4.0 v between pin 1 and 2 there are 11.9 v all in ac
Now I give other measures but these are different because in the previous ones and measured with the multimeter with the tips directly on the pins, in this case I am measuring with the black tip of the multimeter in the heatsink and with the red one I am measuring at each point, it gives me very different measures, and also in dc not in ac pin 1 -27.4 pin 2 - 33.2 ´pin 3 - 27.4 v what I did was follow those lines to the main board and they took me to a group of resistors and diodes pzd3, pzd1, pzd2, pr1, pr2, and I feel hot in that area therefore I will measure these diodes and comment that it happens
Well, check these components, all are ok. Pr24 This price increase therefore replaces it, but it remains the same, the other is that I notice that Pr13 overheats a lot.