Hi, the team does not turn on directly. And half tensions at the exit of the traffic and has nothing. At the entrance of the diode bridge either, all fuses ok so determine that the fault is there
Thanks there I see the part number but I do not see the output voltages that is what I do not find anywhere to buy a similar one
Voltage selector ok. If alternating current. I have 220v. I tell you that at the entrance of the coil the 220v arrive, but at the exit if I measure between 6 and 7 I have nothing ... that's why I assumed the thing about the traffic ... Query you said that the traffic is ok but if between 4 and 5 I measure without continuity that does not mean that this internal fuse is cut? thanks
The 220 are between 1 and 5, the selector is ok and the fuses too ... But at the output I don't have the voltage. What a mistery
Heh! Well I don't know where I should rate you to thank you for the help. Tell me where and I do it, thanks!
I tell you between pin 1,2,3 and 5 there is continuity, between 4 and 5 no. between 1 and 2 there are 3.3 ohm, between 1 and 3 there are 27.6 ohm and between 1 and 5 there are 41.5 ohm. Between 6 and 7 there are between 8 9 10 and 11 there are cont and between 12 and 13 too. Between 6 and 7 there are 2.1 ohms between 8 and 9 4.5 ohms between 8 and 10 7.5 ohms and between 8 and 11 18.8. And finally between 12 and 13 2.7 ohms. That's all the values to see if you see something weird ... Thanks a lot