Sony MHC-EC55 c / transform device. damaged standby

Félix Hernandez
hace 6 años
hace 6 años
Greetings companions, I got this equipment without turning it on for having the primary of the transformer sub 001 open (this tansform. Is that of the Vcc standby) I replaced this transformer with a 10 volt I tried on, audio and everything worked fine. I delivered the equipment and after 2 days he returned due to the same problem, turned off and did not turn on again. When checking the primary of the standby transformer again open, with signs that it had overheated, I asked the customer if they were connecting it in a 220 volt network and he replied that not that they connected it in the same socket where the refrigerator is connected (from 110 vol) I do not understand why this primary winding of the standby transformer opens please listen to suggest thank you. . . .
jomi
jomi
38.143
hace 6 años

Is it plugged into the same outlet as the refrigerator?

Responder
Félix Hernandez
hace 6 años

Thank you I will check and comment

Responder
enigmahernandez
hace 6 años
hace 6 años
If it heats up, then check the secondary output of the StandBy, it might have excess current consumption ... Look at the Service Manual Link: https://elektrotanya.com/sony_mhc-ec55_ec77-ver.1.2-br.pdf/download.html 01) Change safety diodes D051 or close to this Diode. 02) If you follow the standby track and find 302, you measured voltages as indicated in the service manual ... Page 40 Possibly it is short ...
Félix Hernandez
hace 6 años

Companions (as) diode 302, DZ 301, transistors Q306, Q305 and Q303 are not short, I have not tested voltages yet because I have not placed the new transformer at 9 vol

Responder
Félix Hernandez
hace 6 años

Hello colleagues, I do not get diode D 052 and D055 (MC 2838) by which can I replace it ???

Responder
Félix Hernandez
hace 6 años

Hi, hello, I need substitutes for the high-speed diode MC 2838 D052, D055 rectify the standby voltage

Responder
enigmahernandez
hace 6 años

But have you checked that you can remove it from StandBy?

Responder
Félix Hernandez
hace 6 años

If the equipment was on but taking tensions I caused a short in the standby line and the high speed D 055 diode was shorted
I need a replacement or someone who has it for sale thanks for your help

Responder
enigmahernandez
hace 6 años

To actualize:
You can put 2 diodes 1N4148 and adapt them with their cathodes together, that works because they are fast switching diodes (Fast Switching) and their datasheet is very similar, those can be put in those sources Sony, LG
Try them, and tell me please, although it is rare that you do not get that Diode between burned pieces of other equipment ...
Best regards, pr

Responder
Félix Hernandez
hace 6 años

thanks enigmahernandez I will do that because I don't have any scrap of those teams

Responder
enigmahernandez
hace 6 años

If it worked for you, give me a little hand up and solved: D Thank you: D

Responder
Félix Hernandez
hace 6 años

Yes, I worked perfectly enigmahernandez, in standby I measure 16 mA in said line and in ON 76 mA when the CD change mechanism works reaches 225 mA it seems to me that it is super normal I will try it for two days checking primary temperature of the standby traffic

Responder
enigmahernandez
hace 6 años

excellent take it for granted then and if you can help me .. handyman up and fixed:

Responder
Félix Hernandez
hace 6 años

fellow enigmahernandez why I measure 7.8 v in the rectifier that goes to "AC detÇ" in the rectifier of "V STBY" I measure 10.35 v
Shouldn't it be the same reading?
The main transformer heats to 41 C at volume 12 is normal? I don't want to burn the STBY traffic again. . .

Responder
Félix Hernandez
hace 6 años

Is a temperature of 43 C normal in the main stream at volume 13?

Responder
enigmahernandez
hace 6 años

No, it is not normal, it is consuming a lot of current, more than normal. Check the temperature of the power IC. that is cooling well with the heatsink.

Responder
Félix Hernandez
hace 6 años

The power IC measures 43 C and the main traffic 42 C at volume 14 The rectified and filtered Vccs that go to the IC are 33.5 and -33.8 volts

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis