I have a C116 BE longvie water heater and it has been a while since the selector does not regulate the size of the flame well, in the first point it is very low and in the rest it is excessively high. Full maintenance, serpentine cleaning, burners, diaphragm replacement and still the same.
Do not know if there is something that should be done in the part of the regulator of the gas column? It also has a screw that could be of regulation in the part of the burners, but it is quite taken and I don't know what its function is.
Hi. On the axis of the rotary or rotary temperature selector you have a 4-level "ladder" that regulates the opening and closing of the passage of gas to the burners. It must be clean and lubricated. Verify that it has not been spent since in that case it will not act as it should. In these cases it is replaced. regards
I disassembled the selector valve and indeed the piece you mentioned seems very worn, the first points are practically all equal in height, attached the photo to give me your opinion if you can.
These days I will see if I get a spare in a large gas business
I forgot to close this query, recently I went to the largest gas business in the region and they told me that this piece is no longer sold separately, the entire command axis must be changed ($ 700 to 800 approx)