⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta.🔥 Aprovechar oferta ahora 🔥
I have a 20-liter Orbis automatic water heater. The red light was blinking, so I changed the battery. I put a new battery on it and as soon as I put it on it, it gave me a single red light flashing but the green light did not turn on, I tried to open the tap to see if the pilot light was on but it did not. So replace the batteries 3 times with as many new ones but always with the same result, without the green light flashing and without lighting the pilot. Can someone advise me. Thank you
Hi
that marks a blockage, you have to check the electrical terminals of the smoke thermostat and the overtemperature, they know how to make false contact
Check and comment, greetings!
The same problem happened to me.
In my case the problem was in the contact click where the diaphragm goes, it was with tartar, after a clean it worked again well.