Hello people good afternoon, I ask for your help to see if I can solve this problem of hot water. The subject is like that 1 I have little pressure on the hot water line, when I open the shower it takes several minutes to fill the flow of the flower and get out hot. 2 when it comes out hot it seems as if the flow rate is intermittent, could it be that I had sucking air And if I open a little the cold cools in seconds ... 3 The lowering of the tank is individual to the rest of the house, it has a single descent for the 1/2 "thermos and the whole network is also on average but the entry and exit of the thermos is 3/4, can that affect? ??? They recommended me to do the descent of 3/4, is correct or would not modify anything ???? Of course I would appreciate those who can advise me, I understand other issues but in this plumbing nothing. Thank you very much and greetings !!!
mariotti luis marcos
hace 5 años

Hi ; claudio well I'm glad to know that you could solve it thanks for sharing what the fault was greetings from miramar bs as arg

Responder
claudio36
hace 5 años

Thank you Luis, I just have to put a pump on it to have more pressure, I still improve a lot, greetings from Formosa!

Responder
mariotti luis marcos
hace 5 años
hace 5 años
hello: for what you say the pipe is badly sized, the descent has to be a minimum of 3/4 changing that you will gain a little more flow but do not press to have more pressure or lift the tank or place a pump and pressurize check that This clean the inlet and outlet of the thermos can also blow the hot water pipe with air to remove any garbage that may be obstructing the passage of clean water filters of the faucets also the flower of the shower anything comments comments greetings
claudio36
hace 5 años

Hello Luis good afternoon, sorry for the delay in responding, I tell you that after your response I started to review everything in detail, I had connected the water inlet at the exit, I reversed it and I improved a lot, I also sealed all the threads for the doubts, I improve the flow quite a bit, now I only have time and want to haha, make the descent of 3/4 and put a pressurizing pump, so well the main thing that already solves in large part. From already very grateful for your help and your knowledge, thanks Luis until another time, greetings.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis