⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Water Heaters (Calefones)

Calefon Neckar, Chinese, does not turn on at all ...

Anto-sa
Anto-sa
60
hace 5 años
hace 5 años
Hello everyone from Chile, my problem .... Neckar WN10GL heater, turn on, turn on the burner but turn off after 2 seconds. After 5 attempts it turns on well, and there is no problem. Change gas regulator to discard. I kept the same, new battery .... the spark is correct and lights the pilot .... I have not checked the diaphragm, but when I turn it on with the water I take it for granted, the water filter is clean. The water flow is good and the pressure too. Once the heater turns on, turning it off and on again is no problem, turn everything on. But after cooling down after a few minutes the fault continues. I suspect you have to see the temperature sensor that is in the pilot .... apparently it is a thermocouple, but I'm not sure ... will there be a way to test this sensor ?. without having to change it? Greetings from Biobio, Chile
eduardosj
hace 5 años
hace 5 años
Hello, try disarming that sensor that I imagine should be the flame sensor. Remove the cable by rotating the sensor, once separated cut the tip 1/2 cm and reinstall the sensor, test and comment .. send image if you can .. luck.
Anto-sa
Anto-sa
60
hace 5 años

Ok, I see it and I tell you.

Responder
Anto-sa
Anto-sa
60
hace 5 años

Solved, thanks Eduardo ..... I followed your advice, plus a little literature regarding the ionic probe, it is important to consider this detail in periodic maintenance, cleaning ... because these devices are usually installed in kitchens and dirt is dust, tablecloth fibers or not and condensed with grease ..... this causes a lot of dirt inside the water heater .... that is not seen ..... only seen when disassembled.
I hope I have contributed ... and greetings from the Biobio.

Responder
Anto-sa
Anto-sa
60
hace 5 años
hace 5 años
Hello everyone, I continue with the problem, the temperature sensor that has this heater is not bimetallic, from the sensor only a single cable goes to the module, this sensor as tested? Greetings from the Biobio.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis