3/4 nipple input and output infernocarcomidos by rheen thermo oxide

Angel 1pc
hace 6 años
hace 6 años
hello: I have a 50-liter natural gas rheen thermos with lower inlet, 3 years of use and the thread threads of the nipples are all rotten. My question is if I exchange them for other bronze nipples what type of thread sealant could use (that supports the heat of the bottom of the tank and the water)
Angel 1pc
hace 6 años

hello: does anyone know what sealer to use for this case of water and heat from the bottom of the thermos?

Responder
mariotti luis marcos
hace 6 años

Hello, good angel, I'm glad to know that you were able to solve the problem, greetings from miramar bs as

Responder
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. You can use Hidro 3 green sealant (H3) with some hemp strands. It will never lose and if it is of lower load it does not receive much temperature. This corrosion is due to the galvanic torque that originates from being different metals in contact. Regards
Angel 1pc
hace 6 años

Hello: I would have to leave it for more than 24 hours drying out because on other occasions with less time it gave me losses

Responder
servimat1
servimat1
138.835
hace 6 años

There is no need to let it dry. just make skin in 15 minutes. The hemp if it gets wet expands closing the possible leak.

Responder
mariotti luis marcos
hace 6 años
hace 6 años
Hello: you can enable it at the moment, place hemp in the lower part of the thread, then the h3 sealant on tight weapons and you can use it at the moment you should not lose, see if the cupla where you screw the nipple has a stop if you can put a gasket fiber with that there would be no possibility of loss if you do not know how to use hemp you can use high-density teflon greetings
Angel 1pc
hace 6 años

hello: in the week I will try, I hope to loosen the nipples, they would seem to be placed with another type of sealant that if it solidified it will complicate me and there I will ask for more ideas.

Responder
mariotti luis marcos
hace 6 años

If they use a white sealer, it is similar to hydro3, but the galvanized nipples are seized, do not overdo it if they do not loosen heating with a blowtorch

Responder
Angel 1pc
hace 6 años

hello: buy the torch for this job, heat 2 minutes and problem solved came out easily and without moving it, thank you very much Luis

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?