Tervieanque longvie new 80 liters natural gas

OrlandojuanAlbornoz
hace 6 años
hace 6 años
Hello friends of "I repair" I am a new user. Someone could guide me in the possible causes. I have problems with a longvie 80L hot water tank connected to natural gas. The city is below the tank Trmo. Specifically it costs you to light a pilot and does not heat as soon as you get it. And I left it a whole night and a day a little less than the max and barely any more. Someone to guide me. Thank you very much in advance. It is my first msj.
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. If the burner flames are consistent there can be two problems. One, that the base is with tartar and there is no good heat transmission to the water and the other is that there is a loss of water at some point. In this case, the water circulating constantly never gets to accumulate and heat. Do the first test by closing the water inlet valve to the thermos for two or three hours and check if it heats. To do so there is a loss. Otherwise it would be necessary to disassemble the appliance and clean the tartar from the inner pot. Regards
OrlandojuanAlbornoz
hace 6 años

Good friend servimat. I did the maaneobra you told me and effectively warmed up. But I have not found any loss. The thermos is new. So rule out the possibility of tartar. And at the moment I am walking perfectly, the only thing I did is to leave sir water from the water outlet that stops or is a purge. And you wanted that to have been the somucion the truth I don't know, it's the only weirdest thing I did. However I leave a cordial greeting and very grateful for your prompt response and the desire to help. God bless you and I thank you very much for the advice. I will continue to control I hope I have no surprises. Salt

Responder
servimat1
servimat1
138.835
hace 6 años

A pleasure that you solved the problem. Go checking for several days how you behave and see if you can solve it if you continue with the problem. Regards

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis