Hello good afternoon, I thank you that seeing an answer we could solve that the Orbis water heater was still switched on with the closing of the water passage.
Diaphragm was changed, it was not the problem.
The problem was GAS PUSHING AXLE. Which is located above the diaphragm, was oxidized and locked, W40 WAS OILED to loosen and with a tip clamp it was removed, cleaned, lubricated with graphitized grease and ALREADY PERFECT.
MANY THANKS