The serpentine is new, it changed everything because it had sulfated, so it shouldn't be that, now when I arrive I look at the rest and upload a photo. Can it be the magnetic unit of the thermocouple?
hello: the magnetic and thermocouple unit is a security system if I had any problem, I wouldn't turn on the device,.
if long smoke is due to bad combustion it is uncalibrated and you have bad ventilation check the injectors you will melt the new serpentine called another gasist greetings
Hi Luis, I called another gasman, he was the one who told me about the magnetic unit, we still didn't change it since there was no hardware store open when it came. There I added photos. The smoke happens sometimes, and generally when there is a lot of wind. The pilot does not light easy, you have to try several times until it hooks, the injectors may have to do with that too? how can i check them? Thank you!
No, it's still the same, I have to try the magnetic unit to see if it's that, but it still happens that it turns off even if I'm using it
Let's hope so. I will wait for Wednesday to change it, just in case I fuck something and just grab the holiday. Thank you and happy new year!
Well, it wasn't that. I changed magnetic unit and thermocouple because of the doubts that either of them is the one that sometimes failed. I cleaned the injectors of the pilot and neither. It is still hard to turn it on, the pilot turns on perfect but goes off as soon as I release. The new magnetic and thermocouple unit work well, test them separately, and the pilot injector fire touches the thermocouple well also when I leave it armed in the heater.