⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Water Heaters (Calefones)

Skip the built-in thermal wrench of the acualogic hot water tank

Huilen Martel
hace 6 años
hace 6 años
I have an electric water heater which turns on, heats the water and at a certain moment the built-in thermal jumps. I already changed the plug. It is 110 liters AquaLogic brand I would like to know if you can help me with this problem. Thank you
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. Of what value is the thermal that jumps? It has long been installed and working? Regards
Huilen Martel
hace 6 años

The thermal tank heater that comes from the factory incorporated jumps

Responder
servimat1
servimat1
138.835
hace 6 años

Thermoses do not usually bring a thermal but a thermostat. If this is the one who jumps it may have expired and is failing. In these cases it is changed.

Responder
Huilen Martel
hace 6 años

In the end, the problem was the thermostat. Because it does not cut the resistance and shoots with temperature.

Responder
servimat1
servimat1
138.835
hace 6 años

A pleasure that you solved the problem. Regards

Responder
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Hello obviously there is a failure in the thermos or thermal mentioned if it is due to failure, it may be the resistance or a burnt cable whose loss of insulation generates extra consumption leaving the thermos in an overload situation, the protection included if it is thermal it can be due to fatigue of the materials that compose it regards
elektomaq
elektomaq
62.202
hace 6 años

Question:
Do you have a differential switch?
If not, it increases the possibility of what I wrote in response
If yes, check if it works by pressing the test button
Comment

Responder
Huilen Martel
hace 6 años

The cables check them and they have nothing. If it was the resistance, would it heat the water for one day and the other make the key jump?

Responder
Huilen Martel
hace 6 años

It has no differential switch

Responder
elektomaq
elektomaq
62.202
hace 6 años

Yes, you can act after several hours or days,
The question was whether there is no differential switch in the housing installation, not specifically in the thermos. If you have a multimeter check resistance between resistance terminals / thermostat and chassis

Responder
Huilen Martel
hace 6 años

I am going to do the test with the multimeter and if it turns out I warn you. I keep you up to date, thanks

Responder
Huilen Martel
hace 6 años

I am going to do the test with the multimeter and if it turns out I warn you. I keep you up to date, thanks

Responder
Huilen Martel
hace 6 años

In the end, the problem was the thermostat. Because it does not cut the resistance and shoots with temperature.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis