Electric stately heater

Walter Fernandez2
hace 6 años
hace 6 años
Good morning, the query is about an electric hot water tank, it did not heat the water, therefore I took out the thermostat and I found that it had an overheating, which I passed an sandpaper to where the connectors are stuck inside it and I tried it again, which is why it is barely warm in water now. Now turn on a few minutes, and turn off and on again. The thermostat knob turns on after half and almost to the maximum. Less does not turn on the light that shows that it is heating the water. I tried the continuity of the resistance and apparently it is not cut, if it was cut, I would not have to even warm the water, isn't it? What could cause this breakdown? Suppose I change the thermostat, I don't want to break again. What do you think?
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. possibly when the thermostat overheated it went out of range. When the contacts deteriorate, it is best to replace it because by sanding it removes the actual conductive layer from that surface. To test the resistance operation you can connect it directly to an outlet and leave it in operation for about 20 minutes. Regards
elektomaq
elektomaq
62.202
hace 6 años

Clarification:
The resistance can be connected directly as long as it is submerged in water

Responder
Walter Fernandez2
hace 6 años

As the continuity in the resistance was fine I figured it would not be the problem. I will change the thermostat, thank you very much!

Responder
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Hello If the thermostat turns on and off without obeying the temperature regulation, the problem is the thermostat. If the resistance were the problem (which does not heat or little heat) the thermostat in proper operation would give connection and do not disconnect until the water was at cut-off temperature regards
Walter Fernandez2
hace 6 años

Thank you very much, I will change the thermostat.

Responder
Walter Fernandez2
hace 6 años

For the doubts I consult, what delay would the hot water tank have in heating the water? That of 60 lts.

Responder
elektomaq
elektomaq
62.202
hace 6 años

That depends on the initial water temperature and tension at all times, not being a certain value, the result is uncertain. I would say about 3 hours on average the initial heating at maximum temperature

Responder
Walter Fernandez2
hace 6 años

Well, thank you very much for the tip!

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis