hace 6 años
[Img] https://www.yoreparo.com/pregunta/editar/6124015 [/img] IMG_20190703_201812.jpg [3.75mb] IMG_20190703_201754.jpg [3.48MB] IMG_20190703_201746.jpg [2.88MB] Hi, it turns out that you install a rheem 160 AP hot water tank. And I get little hot water pressure in both the bathroom and the shower. They told me to put a pressurizing pump. It is already placed. My question is, which side is the relief valve. If you go after or before the pump. At this moment I am using the hot water tank without the relief valve. In that case. It harms the hot water tank without relief valve. What dou you recommend? . Greetings to all
grillo258
hace 6 años

Hi servimat1. Before I had good pressure until I placed the hot water tank. For example of 20 showers I do. 1 comes out with hot water pressure. Now that you install the pump, it comes out with pressure. And do not need to place the valve (6 Bar). For something this seems to me. I appreciate your comments

Responder
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. The relief valve always goes to the cold water inlet. In your case after the bomb. Do you have low pressure even with a thermo tank? Regards
servimat1
servimat1
138.835
hace 6 años

There must be a problem in the pipe or you may need a vacuum breaker.

Responder
servimat1
servimat1
138.835
hace 6 años

However, a couple of photos of the thermos connection area would be interesting.

Responder
grillo258
hace 6 años

Great later attached picture. Thank you

Responder
grillo258
hace 6 años

I already uploaded the photos. Regards

Responder
servimat1
servimat1
138.835
hace 6 años

Place it with a T before the pump or in the flexible inlet. It is a measure of protection. The strange thing is that with a new installation you have pressure problems.

Responder
servimat1
servimat1
138.835
hace 6 años

To place the valve use the same T. Remove the nipple and screw the T into the pump. On the between thread or thread with nut screw the flexible. What if, you can barely replace the nipple in the hot water outlet. It receives the heat of combustion from the inside of the thermos constantly and usually breaks as they dry out. They are replaced by another of the same diameter and length but in epoxy iron.

Responder
grillo258
hace 6 años

Ready genius, thanks a lot

Responder
Walter dal farra
hace 6 años
hace 6 años
Hi CRICKET: as if to start the relief valve, it goes at the entrance, but I don't think it's the valve you refer to, those thermoses, they have a valve at the exit, it's inside the thermos, I take them out, since they usually give many problems. LUCK
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis