If the filter is canceled, it does not affect the operation of the washing machine, you have to bridge it by joining the cables of the same color, brown with brown and light blue with light blue, greetings.
Before canceling the filter, check all connections for false contacts, greetings.
Hello, open a new question with your problem, here we are trying to assist another person with a different problem, regards.
Dear, I tell you to perform the following tests .... I measured the voltage in the network filter ok ... I measured the voltage in bba 135V ... I measured the voltage in phase and neutral block 130V ... I made a bridge in a block bridge with a block connected (the two brown wires) open electro valve starts filling but with display off.
What would be the diagnosis? ... With what continued?
Thank you...
What tension is in your country? If there are 220 and 135 reach the peripherals, we must see where the voltage drop occurs, he says, greetings.
Dear, thanks for the help ... disarm until the plate arrived and I found a visibly deteriorated area x some short, apparently in one of the washes overflowed with foam and came to be introduced to the plate by the soap dispenser ... I guess it is irreparable and the only solution is to change the plate.
Besides that should I check something else? I would like to upload some photos but I don't know how, so you can see where the plaque was damaged.