Hello friends, could you help me with some questions, when diagnosing why I did not turn on the "koblenz jazmine" washing machine just to make an attempt to start as if it would stick, test the starter capacitor and give me only 3uF which was 50uF so I assumed that it was only time I had no time to check the motor and I only bought the capacitor, because I already tried the same thing and only started with the help of the hand either to the left or right. I uncovered it and I found that both the rotor and the stator were already very rusty I proceeded to sand them and it was very good I reassembled it and check that it will rotate without anything stopping its movement and already when it connects it the same it is left wanting to turn XD but it doesn't do it if it isn't with help. It should be mentioned that the cables for the capacitor and line are well connected and also that slice that is direct and the same happens. My question is how to know if the engine still works if there is no burning smell or visually there are defects in the windings and there is no continuity between the housing and windings, if it is not grounded. P.S. If it starts with help and already working I stop it with my hand I do it without problems. thanks friends. [Img] https://cdn.yoreparo.com/uploads/imagen_post/0002/45/46dcf40cac7624b11262e0b09ec65612b45d740d.png [/img]
PETE 17
PETE 17
272
hace 5 años

Hello friend, that engine does not work anymore because the work winding is no longer useful, you need to wind it up or buy it again. The two tests you did are adequate, that is, if you have to help it turn and stop it without much force when it is turning

Responder
Adrián Silva5
hace 5 años

Thank you very much friends, for clarifying that these tests are appropriate. I have just returned from an electrical service and I check the 3 cables with a test lamp that I have to see if there is continuity with each other. In the line and one end there was and between the line and the other there is not. And he told me "it's open" that's why he has no strength. It coincides in what everyone tells me. I just wanted to know if there were no more tests.
Thank you very much for your time.

Responder
lusangor
lusangor
56.366
hace 5 años
hace 5 años
Hello, the problem you have is clear, the coils were probably damaged by having the capacitor or capacitor bad. Even if nothing is burned, the coils may be unusable. The best thing is that you go to a good embobinator and advise you. Regards
pablo lamas
pablo lamas
2.661
hace 5 años
hace 5 años
Hello, damaged engine starter coil, regards.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis