Good. Already make the measurements. Without blowing, I measure continuity between 11 and 12 and there is indeed continuity. Then blowing through the pipette, I measure continuity between 11 and 12 and there is no continuity, then I measure between 11 and 14 and there is continuity. I keep blowing but I get to have continuity between 11 and 16.
So is it working wrong?
It is not working badly, when blowing to the maximum there should be continuity between 11 and 16.
Good. Already make the measurements. Without blowing, I measure continuity between 11 and 12 and there is indeed continuity. Then blowing through the pipette, I measure continuity between 11 and 12 and there is no continuity, then I measure between 11 and 14 and there is continuity. That already assures me that the pressure switch is working well?
Actually, eye, do not touch the screws of the pressure switch, as you can deconfigure it