Microwave Whirpool 6th Sense goes out

Ayi Zurita
hace 5 años
hace 5 años
Good friends: I tell you the problem of my microwave, I put it to work for example in the Defrost function that being 6th Sense the microwave only determines the defrosting time, the issue is that it starts normal and within a few minutes it stops to operate, the fan and the time indicator display stop. When using other functions of a few seconds for example heating 30 sec or 4 sec, it works normally. Thank you very much in advance for your answers !!!
tecnico54
tecnico54
22.006
hace 5 años

the display is completely turned off too = ????

Responder
Ayi Zurita
hace 5 años

that is, the two dots remain nothing more ... not that it indicates END or something

Responder
tecnico54
tecnico54
22.006
hace 5 años

you should check the door swichs you want with longer time disconnect and that's why you stop the microwave

Responder
Luis Alfonso Galindo Gome
hace 5 años

Check overheating in the area where the thermal sensors are, usually in series with the circuits. at the moment in which it fulfills the function of over temperature protection, the oven is completely switched off, for a certain moment.

Responder
Ayi Zurita
hace 5 años
hace 5 años
Thank you very much for the answer, the truth is that if you have lint and dirt, I will clean to see how it works later and I tell you! (I am not a technician)
hgpaccio
hgpaccio
1.515
hace 5 años
hace 5 años
you do not clarify if you are a technician, so I am going to ask something maybe basic, but that is not too much to contemplate ... did you notice that the rear air inlets are not obstructed by dirt? In some cases, dirt and grease adhered lint obstruct the ventilation air inlets. or inside, if you have disassembled it ... also check that the ventilation system works properly, turning the fan freely. It usually happens that by not ventilating well, the safety thermoswitch causes the operation to stop.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis