good night my friend, if it is digital and has 3 swich the first one is the one for the button for the other door in the middle and another one above I explain you check all cables the thermal fuse and the glass fuse the diode everything is ok its capacitor was bad I change it and still does not heat I do not see another fuse so I ask that if the swich on the card does not heat if they are bad and how they are tested or if you could help me on this
greetings friend just from venezuela, if I test magnetron and perform the continuity tests, the 110 v shot is perfect today if the rain lets me out I will look for a magnetron and another transformer to do the test and the primary ones measured them in ohm and its value is very low 00.1 and I understood that it is 3 to 5 I don't know if I'm wrong? the secondary the ohmiaje if it's okay now friend hector to measure the voltage of the primary conetco the team excuse my doubt
Friend, I am sure that the problem is the magnetron, not the transformer, this fault is given by the magnetron, try another magnetron that is good and you will see greetings.
good afternoon, greetings countryman as you know the situation of our country venezuela lasted up to months without internet indeed it was the magnetron thank you very much you will have a page on youtube with tutorials or something like that greetings
Ok friend if it was the magnetron because you didn't give me the solution,? Did you give it to the colleague that his answer was not the solution? I do not understand
Don't worry, friend, that happens if you want to vote, I like it in my answer and ready a greeting.