hello, the problem is that the 220v that goes to the traffic is not cut and the magnetron is activated as soon as it connects to the network, I am checking the board but I cannot find the ploblem, could it be the integrated one?
Hello, if it could be that the controller is sending voltages to the relay without doing the respective programming. As for the fan, plate and light are also activated or is it just the transformer?
Hello friend greetings for what you comment the problem is in the large reley of the electronic board which controls the large transformer of the high voltage insurance is flamed its internal contacts and stayed stuck to know how to disconnect the two wires that feed the large transformer and place a focus on those two wires put the microwave to work or connect it to the power grid if the light turns on without giving any function. Tap this reley if the light goes out. I commented and should be replaced by one of the same characteristics to the original to solve the fault greetings.
Atte Hector from Venezuela