hello colleague greetings, let's see the aerial goes appreciation as the colleague comments okay okay my question is when you say that it turns off that you mean the displey goes off? or is it just for the meter? comment to help you
greetings colleague hector not the paste was placed in the cavity of the oven where the antenna is inserted .... ok friend hector turns off the display goes off everything
hector is proven with 2 magnetrons and nothing equal ignites and when it is heard that the magnetron starts it turns off all display
but it does not make much sense since you remark that as soon as the magnetron is turned on the permitter is triggered these permisores are designed so that when the magnetron passes the working temperature this acted and it turns off the microwave in that short time it is impossible that exceeds that temperature or me Am I wrong, colleague, Leonard?
where you put the paste on the outside or inside the hole where the antenna? and because you put this catch had a hole?
yes and thank you for responding if there was hay as eaten by the rust and bow to the magnetron if inside the hole where the antenna
Ok, look, you must paint that paste to cover it since this is going to make arcs, now my question is how is the capacitor and the diode are correct? I already tried with others?
thanks for replying hector the truth is not tested with another capacitor nor tested with another diode i will have to test test one question i test with another capacitor even though it measures well !!
I explain better the capacitor is in good condition but the truth is not tested with another capacitor I will do the test and I will keep you informed
if you remember that these components can measure well but in a matter of work fail test with another trainer to leave doubts porq of true this fault this racimara friend and you tell me the second magnetron that you placed this is sure this good?
that such good afternoon friend hector change diode hv capacitor thermistor and brother nothing goes off only if I take off the transformer wires work normal
change the magnetron for another one, I know that you say you already put another one but it can also be bad, put a third and comments
the truth friend hector I have tried magnetrons of other furnaces that are working and the fault perciste
Good friend test with another transformer of high tencion test with another of any microwaves and comments
that such friends happy night ....... friend follow the problem of the oven and you change the transformer the capacitor the diode hv you e proven several magnetron and bnada really do not know what to do
friend thanks for responding if it is quite rare the only way it works is to disconnect the wires from the magnetron
friend lolita de verda that rare this fault colleague let me analyze well to see that I advise
friend analyzing everything commented.and all he did for me is the stick that you put him that is doing that the microwaves are not directing well that makes it shoot sounds a little crazy.but that's what I think is happening friend
hector a greetings I have good news and solve the fault was effectively the stick that had placed in the cavity of the microwave oven good I have to thank you friend and also the technician 2015 for your valuable help a hug
hello, colleague, greetings, look, just look at it, I said that it was the wrong thing to do. You did not give me the solution. I told you where the problem was, my friend. I could not answer the moment because I had trouble getting to the page and I'm back. Well the important thing was that I solve it but next time do not give the quick solution, wait for one to respond so that you give the solution to who actually gave you greetings friend until another opportunity.
hello tech friend 2015 if it actually turns on normal but when you hear that the magnetron is turned onc the display turns off and thanks for replying technical friend 2015
ok tech friend tomorrow I changed the thermostat and I will keep you informed and thanks for your valuable collaboration