MICROWAVE WHIRLPOOL VIP 34 GETS BUT NOT WARM

carlos2017
hace 6 años
hace 6 años
GOOD MORNING PARTNERS I'M TREATING TO REPAIR A MICROWAVE WHIRLPOOL VIP 34 THAT RINGS AND WORKS BUT IT DOES NOT HEAT. I AM NEW AT THIS. I'VE ALREADY CHECKED ALL COMPONENTS THAT I WOULD LIKE TO CAUSE THE FAILURE. HERE IS THE MEASUREMENT OF THE COMPONENTS: [list] [*] CAPACITOR = 1.1 MICROFARADIOS = OK [*] MAGENTRON COIL RESISTANCE MEASUREMENT = 0.6 OHM [*] CAPACITOR 2 (OTHER CAPACITOR HAS THIS MICROWAVE I DO NOT KNOW WHAT FUNCTION MEETS) 0.45 MICROFARADIOS = OK [*]TRANSFORMER: [*] PRIMARY COIL: 1.8 OHM [*] SECONDARY COIL: 103.4 OHM [*] MAGNETRON COIL: 0.6 OHM [*] DIODIO HV: PROBE WITH A LAMP SERIES AND REDUCE YOUR INTENSITY OF LIGHT [/list] I DO NOT KNOW IF I MISS SOMETHING FOR REVIEW OR THERE IS SOME MEASUREMENT THAT I AM WRONG BUT IF SOMEONE CAN HELP ME TO SOLVE THE PROBLEM I WOULD COME OF 1000 !! FROM THANKS TO ALL FOR THE HELP
samuel2015
hace 6 años
hace 6 años
if all is well the problem may be the magnetron unloaded test with another magnetron to see if it follows the fault
CESAR ALEX
CESAR ALEX
40.413
hace 6 años
hace 6 años
Well, for the time being you did not measure the VOLTAGE (120 or 220 VAC, according to the home electrical grid) on the primary side of the High Voltage Transformer. This is made present once x time has been programmed and the Start-Start or Warm-up function is typed. If that voltage is present, then you will have absolute reason that the problem is in the HIGH VOLTAGE SECTION and the main suspect will be Magnetron. Some microwaves have a fuse of High voltage and very low amperage associated to the lines of the Magnetron. It is not other to review it if it has. If this voltage (120 or 220) does not appear on START, then it is a matter of checking DOOR SW, RELAY (in addition to electronic components associated with this) and the wiring, being possible to find some with a carbonized terminal or with an open line .. Regards
carlos2017
hace 6 años
hace 6 años
GOOD AFTERNOON COMPANIONS APOLOGIZE THE TARDY OF MY RESPONSE. IT RESULTS THAT THE MICROWAVES CAN ALREADY REPAIR LOST FOR SO MUCH WORD BUT KNOW THAT IT WAS? A PAIR OF TERMINALS WAS BROKEN AND DID NOT MAKE GOOD CONTACT SO CHANGE IT AND NOW THE MICROWAVE WORKS. THANK YOU VERY MUCH SAMUEL AND CLEAR BY TAKING THE NORMS TO RESPOND
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis