⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
TVs

triac test

alcides alvarez
hace 5 años
hace 5 años
Good afternoon companions, this day a friend brought me a pair of triac Q6016LH4, which I was measuring but I have doubts about whether they are good or not. With the multimeter in resistance 100 ohm, these measure 58 ohm between MT1 and G and between MT1 and MT2, it is zero, I also made a connection to light a lamp with 110v but, my doubt is if when disconnecting the r of MT2, the Should the lamp be on?
felipe  antonio
hace 5 años

partner. I will send you the diagram of a triacs tester, with which a technician tests the washing machine triacs. You already have it armed, this way you do a dynamic test, the focus you use is 100w. comment. greetings everyone. Felipe ascencio

Responder
alcides alvarez
hace 5 años

ok i would appreciate it

Responder
alcides alvarez
hace 5 años

Thank you all for your contributions, greetings and success.

Responder
antony28-80
hace 5 años
hace 5 años
alcides alvarez, the r you have connected goes from MT2 to GATE? or from MT2 to where. look I hope I'm not mistaken, the triac is an electronic swicht between MT1 and MT2 and GATE is the shot, then if you connect a lamp to 110 and a line you pass it through the legs MT1 and MT2 in seri, when making a momentary bridge between gate and mt1 must turn on and if you disconnect that bridge from the gate it should not be turned off until you take the power supply to MT1 or MT2. I hope I helped you salu2
alcides alvarez
hace 5 años

Ok but that kind of triac (q6016lh4) would behave the same - they are from a washing machine.

Responder
antony28-80
hace 5 años

every triac must behave the same, and depending on its characteristics it is faster to swicheo or cut etc ...

Responder
alcides alvarez
hace 5 años

I understand that these control the motor, on one side and on the other, so that they would be damaged, since when the r is disconnected, the lamp goes out.

Responder
alcides alvarez
hace 5 años

By the way the r is connected from MT2 to GATE

Responder
felipe  antonio
hace 5 años
hace 5 años
felipe  antonio
hace 5 años

As you can see there are few pieces. The only thing that leaves you out are the 3 wires and an aluminum base with a screw to adjust it to the heatsink. Master Antony, you're right, you can check the washing machine triacs, like the motorcycle ones. I hope it serves you. Greetings everyone.

Responder
antony28-80
hace 5 años

Felipe Antonio thank you very much for the compliment ,,,

Responder
felipe  antonio
hace 5 años

Master Antony
good evening.
It is no compliment, it is the truth. Knowledge and explanation are the essentials. Your data serves as a reference and in this case both things are apòrta you.
Is a pleasure meeting you.
Philip ascended.

Responder
antony28-80
hace 5 años

Thanks again Felipe and well here we are to learn and teach, hopefully we never lose that goal. salu2

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis