⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
TVs

Hitachi Canyon TV

Sofy2603
hace 5 años
hace 5 años
The TV does not turn on the only thing that it does is that when I connect it to the mains it makes it turn on and protect myself, I hope you can help me I leave photos of the back part the model is 50ux58k 20180404_153748.jpg [3.71MB] 20180404_153754.jpg [3.12MB] 20180404_153759.jpg [2.99MB]
GABRIEL MUÑIZ
hace 5 años

Hi Sofy
Do you know electronic, it is seen that there are overheated things near the stage of horizontal deflection and high voltage; I would start by checking cold welds.

Responder
Sofy2603
hace 5 años

Grqcias for answering my friend Gabriel, I almost don't know about electronics but I like to learn and solve the two plates that it takes, change horizontally and vertically and nothing remains the same, protect yourself.

Responder
GABRIEL MUÑIZ
hace 5 años
hace 5 años
Sofy In these electronics tasks you don't have to change the pieces to change them. It is better to remove the piece under suspicion and try it; If it is in good condition, return it to your site. I tried to locate the service manual, but I only found this one attached: [url = / ver-adjunto / aHR0cHM6Ly9jZG4yLnlvcmVwYXJvLmNvbS91cGxvYWRzL2RlZmF1bHQvMDAwMy81OC81MFVYMThCLTg0NzI0LnBk/gta/b25/b25/b25/b25/b25/chtach/chtch/chtch_ch You mentioned that it is protected. If it is compatible with your TV model, on page 32 you will find the deflection protection part (both horizontal and vertical), in the upper left part of the diagram. What you are going to check are the voltages, since basically the protections are handled as voltages. There is a protection that I did not see is that of ABL, and is associated with the flyback, along with a sensing circuit of the same. In any case, there is also theory of the device in the same manual and the procedures to follow during the service. It considers that there is high voltage inside the device, between 32 and 36 kV to activate the anodes of the kinescopes, so it is necessary that extreme precautions when making measurements near the flyback, in addition to the focusing voltage that can be between 5 and 10 kV . Luck

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis