⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
TVs

Image failure

guadis bermudz
hace 6 años
hace 6 años
A cordial greetings to all, this cyberlux tv with chassis 34B1 presents / displays a flaw in the image that for me is something strange because it had not appeared to me; it turns on normal but after about five minutes it starts distorting the screen with colored stripes from the bottom up (also the audio is distorted) until the screen is totally covered with stripes that can not see the image, I changed capacitors in the horizontal part to discard that part and nothing, with a PC fan I was placing it in several parts of the chassis and in the front part of it carries the Q802, Q804, R826, R822, R823 and R709 is normalisa when I leave serca of those components, and I changed those transistors resistors and diodes but I did not achieve anything only with the fan is that it stabilizes, I upload an image so they have an idea of ​​the fault
francisco angel
hace 6 años
hace 6 años
look me testetia with fault detector is a spray that freezes has a nozzle that you can cool each component so you detect which is in defective component, but otherwise if you start well look first the area, reduce as much as possible and with the welder hot you support it above the components to see which is the one that produces the defect
francisco angel
hace 6 años

fix the voltage of the integrated if it is correct by the doubts if it is a little high happens that and by the doubts changes the crystal if it goes of frequency also happens that if it continues doing it you have to change the jungle

Responder
artion2016
hace 6 años
hace 6 años
SOLVES ALL WHERE THE YUGO CABLE IS ALL THAT PART MEDI VOLTAJES OF SELECTOR AND REVISES IF HEAT THE JUMGLA
guadis bermudz
hace 6 años

Well thanks to the friend artion2016 and francisco angel for their contributions, the friend artion suggested that I test if the micro jungle was heated and actually overheating, I managed and I put a heatsink and is working until the times well, of course this is while getting the integrated, now my question, is damaged the micro or will be some component altered?

Responder
artion2016
hace 6 años

must be the jumgla q is damaged is very typical of these chassis q damage the jumgla

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis