About 6 years ago they gave it to me and I didn't turn on anything, I changed some capacitors that were defective and replace them with others of the same value but higher voltage and it went well. I checked them and they were fine just in case I changed them anyway and still the same problem the only one that doesn't change is one of 100uf by 400V assuming I was in condition
Check if the voltages remain stable on the CN902 connector after it is turned off, there must be 12V on pins 6 and 7, and 5V or 3.3 on pins 9 and 10.