⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Monitors

Viewsonic Monitor Va1703wb shuts down.

horacio001
hace 6 años
hace 6 años
Hello community, my problem is the following: I have a Viewsonic Va1703wb monitor, it shows the image and turns off the second after turning it on, it was showing symptoms, it was difficult to acquire all the brightness, it began to get a pinkish color on its sides until it acquired its full brightness. Now it only turns on a second at very low brightness and turns off. I would appreciate if you could guide me in the problem, thanks.
Carlos Quiroga
hace 6 años

You checked something, it seems to be a problem in the power of the backlight.

Responder
horacio001
hace 6 años

About 6 years ago they gave it to me and I didn't turn on anything, I changed some capacitors that were defective and replace them with others of the same value but higher voltage and it went well. I checked them and they were fine just in case I changed them anyway and still the same problem the only one that doesn't change is one of 100uf by 400V assuming I was in condition

Responder
Carlos Quiroga
hace 6 años

Check if the voltages remain stable on the CN902 connector after it is turned off, there must be 12V on pins 6 and 7, and 5V or 3.3 on pins 9 and 10.

Responder
horacio001
hace 6 años

I'm going to review them and I tell you, thank you very much for guiding me Carlos.

Responder
Carlos Quiroga
hace 6 años

Perfect, then close the post.

Responder
josduart
josduart
4.282
hace 6 años
hace 6 años
On the Internet you can get the service manual, and with that document you can make a review according to Carlos Quiroga's suggestion to the entire power system (source) if the voltages are present to begin to locate the cause of the fault. Regards ... we hope you are lucky
horacio001
hace 6 años
hace 6 años
Finally solve the problem. It was one of the fluorescent lamps that did not work well and then the inverter shuts off as a protection measure. The reddish color prior to the problem was an indication that the incandesence of the lamp was running out.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis