Calibrate Tecnocor PPN-40, password 7931 does not work

Ciclotron
Ciclotron
237
hace 5 años
hace 5 años
Hello colleagues, I am trying to calibrate this Tecnocor PPN-40 scale. I have already done the calibration to other PPR models without problems, but with this I cannot enter. Right here I have seen solutions that comment on using different procedures but none have worked for me, I don't know if I'm doing something wrong, if they help me. The procedure that I believe is the correct one is that you hold down the M1 key while you turn on the scale and after a few seconds the message pwd appears on the screen, then type 7931 and then again M1, and then He supposes that he should go to the parameters but he stays for a while and then enters normal mode. I thought maybe it wasn't the right key but I've been searching and I can't find anything else. I have also tried leaving the pre emp. When turning it on but it goes into normal mode, or I do it with the X key, but nothing, also remove a jumper marked as J5 that commented on another post but not even that way. I don't really know what the correct procedure is, and I just need to calibrate it so I can deliver it to the customer. The scale is like that of the image with LCD displays (they are not red LED display, those if they enter with the first procedure I describe), but the keyboard is the same although with other colors, but they are the same keys and positions. [img] https://adjuntos.yoreparo.com/imagen_post/0005/22/25861caaaaaaaaaaaa img]
enrique fernandez
hace 5 años

Upload photo of the balance

Responder
Ciclotron
Ciclotron
237
hace 5 años

Hi Enrique, I have already uploaded the images, and thanks for your interest

Responder
enrique fernandez
hace 5 años
hace 5 años
Review this post and comment. https://www.google.com/amp/s/www.yoreparo.com/es/balanzas/preguntas/amp/646504/bascula-tecnocor-ppr-40-raduraada-no-es-la-ppn-30
Ciclotron
Ciclotron
237
hace 5 años
hace 5 años
Hi Enrique, thanks for taking the time with this matter, look, I already checked that post and it is about a PPR in which if the 7931 key works, even then after several days of trying to finally find the solution. In another technocor PPR-40 of red numbers when arriving at where PWD appears intentionally type a different key to 7931 (that if it works in that one) to see what it was doing, and does exactly the same as the PPN-40 that I cannot calibrate, does a long beep and then enters normal mode. So I thought, "the procedure is correct, but the key is incorrect," and I became more convinced that "PWD" is an abbreviation of PASSWORD. For these PPR and PPN models it is the same procedure but different keys, so I focus on looking for another password, but no matter how much I dug I found nothing, until trying many combinations of words came this ...: https : //www.yoreparo.com/balanzas/preguntas/914126/no-calibra is a post from 7 years ago that in the title does not indicate brand and model, "thank you very much victorhugoramirezg!" : D password 8624, liiiiiiistooooo !!!!!!
enrique fernandez
hace 5 años

Thanks for sharing the password

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis